Skip to main content

Table 5 The diagnostic accuracy of SIS and hysteroscopy for specific pathologies

From: The efficacy of hysteroscopy for endometrial pathology: the experience of a university clinic on diagnostic accuracy and the comparison with the other methods

HYSTEROSCOPY
Pathology Sensitivity Specificity PPD NPD LR+ LR- False (+) False (−)
% % % % % % % %
Polyp 83.9 63.0 74.6 75.2 2.26 0.25 16.1 37.0
Myoma 80.0 92.4 43.2 98.0 10.5 0.21 20.0 7.6
SIS
Pathology Sensitivity Specificity PPD NPD LR+ LR- False (+) False (−)
% % % % % % % %
Polyp 87.2 33.3 71.4 57.6 1.30 0.38 12.6 66.7
Myoma 71.4 92.3 52.6 75.2 9.27 0.30 28.2 7.7