Skip to main content

Table 3 POP-Q values at baseline and at the last follow-up in patients in the two study groups

From: Transvaginal cystocele repair using tension-free polypropylene mesh at the time of sacrospinous colpopexy for advanced uterovaginal prolapse: a prospective randomised study

POP-Q measurements (cm)

No-mesh group (n = 63)

Mesh group (n = 53)

p value

Baseline

Follow-up

Difference

Baseline

Follow-up

Difference

Point Ba

4.0 ± 2.2

−1.0 ± 1.9

−5.0 ± 2.6

4.0 ± 2.0

−2.2 ± 1.3

−6.2 ± 2.1

0.004

Point C

4.7 ± 2.5

−4.8 ± 2.8

−9.5 ± 3.5

4.9 ± 2.2

−6.0 ± 2.2

−10.9 ± 3.3

0.024

Point Bp

3.9 ± 2.2

−1.8 ± 1.1

−5.7 ± 2.3

3.7 ± 2.3

−2.4 ± 0.6

−6.1 ± 2.4

0.322

  1. Data are mean ± SD. The POP-Q measurements are as recommended [9]. Point Ba is the anterior wall, most-dependent part (in centimetres); point C, cervix or vaginal cuff (in centimetres); point Bp, posterior wall, most-dependent part (in centimetres)
  2. POP-Q pelvic organ prolapse quantification