Skip to main content

Table 4 Diagnostic accuracy of HyCoSy compared with hysteroscopy ± laparoscopy in diagnosing female genital tract congenital anomalies

From: The Thessaloniki ESHRE/ESGE consensus on diagnosis of female genital anomalies

Study

Cases (n)

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

Accuracy (%)

Ludwin et al. [38]

117

94

83

99

65

85

Ludwin et al. [37]

83

96

89

99

73

89

De Felice et al. [14]

104

100

100

100

100

100

Guimaraes Filho et al. [30]

55

100

94

73

100

92

Valenzano et al. [58]

54

100

100

100

100

100

Ragni et al. [50]

98

91

100

100

99

98

Alborzi et al. [3]

186

91

100

100

96

97

Dodero et al. [17]

52

100

100

100

100

100

Brown et al. [7]

46

100

100

100

100

100

Soares et al. [55]

65

73

100

100

97

93

Alatas et al. [2]

62

100

100

100

100

100

Goldberg et al. [23]

32

100

100

100

100

100

Keltz et al. [34]

18

100

100

100

100

100

Mean (95 % CI)

 

95.8 (91.1–100)

97.4 (94.1–100)

97.8 (93.3–100)

94.6 (87.6–100)

96.5 (93.4–99.5)

  1. HyCoSy hysterosalpingo-contrast sonography, PPV positive predictive value, NPV negative predictive value, CI confidence interval